HV-Cable

HV-Leitung High voltage starts where signal voltage stops.

For cables U_max is the maximum DC voltage value or the peak AC voltage. In sinusoidal voltages the rms value amounts to 1/SQR(2) of the peak voltage. The cable test voltage is significantly higher. In connectors must distinguish between the dielectric strength at completed connectors (plugged counterpart) and nonclosed (open) connectors. The uncompleted connectors voltage stability is much lower, because leakage currents can build on the outside. Example: SHV-Connector U_max completed 9 kV DC, non-closed 3,5 kV DC. Applications: Measurement, internal wiring or for outdoor use, suitable for general application of high-voltage.


Pictures of HighVoltage-Cables 1.4kV

RG58
RG58

Pictures of HighVoltage-Cables 3kV

LEMO 140470
LEMO 140470

Pictures of HighVoltage-Cables 5kV

RG59
RG59

Pictures of HighVoltage-Cables 9kV

LEMO 106330 LEMO 131221
LEMO 106330 LEMO 131221

Pictures of HighVoltage-Cables 20kV

LEMO 121221 LEMO 122222
LEMO 121221 LEMO 121222

Pictures of HighVoltage-Cables 30kV

LEMO 130660 LEMO 130666
LEMO 130660 LEMO 130666